BYDTZ - BLACK DEVELOPER FOR DC-5690

  • MSDS: BYDTZ
  • Manufacturer: MITA INDUSTRIAL CO LTD
  • Product Name: BLACK DEVELOPER FOR DC-5690
  • National Stock Number: 6850-00N061993
Product Identification

Product ID:BLACK DEVELOPER FOR DC-5690
MSDS Date:01/15/1993
FSC:6850
NIIN:00N061993
MSDS Number: BYDTZ

Responsible Party
MITA INDUSTRIAL CO LTD
FAIRFIELD, NJ 07004-0008
US

Emergency Phone: 201-808-8444

Info Phone: 201-808-8444

Cage: 65678

Contractor
MITA INDUSTRIAL CO.LTD;MITA COPYSTAR AMERICA,INC.
813 HASBROUCK HEIGHTS, NJ 07604-3110 US

Telephone: 201-288-6900

Cage: 65678

Ingredients

HEMATITE; (IRON OXIDE)

CAS: 1317-60-8

RTECS: MH7800000

Fraction By Weight: 68 +/-2%

OSHA PEL 10 MG/M3 (MFR)

ACGIH TLV: 5 MG/M3 (MFR)


ZINC OXIDE (SARA 313) (CERCLA)

CAS: 1314-13-2

RTECS: ZH4810000

Fraction By Weight: 19 +/-2%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


MAGNESIUM OXIDE

CAS: 1309-48-4

RTECS: OM3850000

Fraction By Weight: 5 +/- 2%

OSHA PEL 15 MG/M3 PARTICULATE

ACGIH TLV: 10 MG/M3 FUME


CARBON BLACK

CAS: 1333-86-4

RTECS: FF5800000

Fraction By Weight: 1 +/- 2%

OSHA PEL 3.5 MG/M3

ACGIH TLV: 3.5 MG/M3


COPPER OXIDE

CAS: 1317-38-0

RTECS: GL7900000

Fraction By Weight: 5 +/- 2%

OSHA PEL 1 MG/M3 (CU)

ACGIH TLV: 1 MG/M3 (CU)

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MINIMAL RESPIRATORY TRACT IRRITATION
MAY OCCUR AS W/EXPOSURE TO LARGE AMOUNTS OF ANY NON-TOXIC DUST.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
RESP) . SKIN:WASH W/SOAP & WATER. EYE:FLUSH THOROUGHLY W/WATER FOR
AT LEAST 15 MINUTES & SEEK MEDICAL TREATMENT. INGEST:DILUTE STOMACH
CONTENTS W/SEVERAL GLASSES OF WATER & SEEK MEDICAL TREATMENT.

Fire Fighting

Extinguishing Media:WATER, FOAM OR DRY CHEMICAL. IF PRODUCT BECOMES
INVOLVED IN A FIRE, USE A CARBON DIOXIDE EXTINGUISHER.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE UNDER NORMAL STORAGE & USE
CONDITIONS.

Accidental Release

Spill Release Procedures:CLEAN UP W/VACUUM CLEANER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:CLOSE CAP TIGHTLY & STORE IN A COOL,
DRY & DARK PLACE.
Other Precautions:AVOID COMBUSTION. AVOID INHALATION, INGESTION, SKIN
OR EYE CONTACT.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . NONE REQUIRED UNDER NORMAL USE.
Ventilation:NONE REQUIRED UNDER NORMAL USE.
Protective Gloves:NONE REQUIRED UNDER NORMAL USE.
Eye Protection:NONE REQUIRED UNDER NORMAL USE.
Other Protective Equipment:NONE REQUIRED UNDER NORMAL USE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MP:>2372F,>1300C.

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:SUPP DATA
Spec Gravity:1.8 (H*2O=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:FINE BLACK POWDER; PRACTICALLY ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE IN NORMAL HANDLING & USE.

Disposal

Waste Disposal Methods:DISPOSE I/A/W LOCAL, STATE & FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.